顾庆华
(神华国华太仓发电有限公司,江苏太仓港口开发区滨海路28 号,215433)
【摘 要】 监督锅炉受热面结垢状况的传统方式是,在机组停运检修中割取受热面管样,然后进行垢量分析,是一种“事后分析”模式,受检修工期的限制,隐患的发现和治理往往要延至下次检修。而今用机组在线数据连续监测运行中
锅炉压差(给泵出口压力与启动分离器出口压力的差值)变化,作为受热面结垢状况的化学
监督手段,这是一种状态监测模式。可以变“事后分析”为“状态监测”,隐患的发现与治理大大提前。国华太电的状态监督实践,证实了这种方式的有效性:不仅大大提高了超临界机组监控水平,且使机组隐患得到及时、彻底的治理。
Boiler differential pressure curve in supercritical DC apparatus chemistry surveillance's application
Gu Qinghua(Shenhua national essence Taitsang generates electricity the Limited company ,Jiangsu Taitsang harbordevelopment zone Binhai Rd. 28, 215433)
ABSTRACT: The surveillance unit heating surface scaling condition's traditional way is, in the unit suspends shipment in theoverhaul reaps after the heating surface tube type, carries on the filthy quantity analysis to obtain, is one kind “analyzes the pattern
afterward”, is overhauled the time the limit, the hidden danger discovery and the government often must delay until the next timeoverhaul. At the present uses in the unit online data continuous monitoring movement the boiler differential pressure (for pump outlet
pressure and start separator outlet pressure differential value) changes, takes the heating surface scaling condition chemistry surveillance method, this is one condition monitor pattern. May change “analyzes is afterward” “the condition monitor”, hidden danger discovery and government big ahead of time. The national essence too electricity's condition surveillance practiced,confirmed this way validity: Not only enhanced the supercritical unit to monitor the level greatly, and enabled the unit hidden danger to be under early, the thorough government.
KEY WORDS Boiler differential pressure ,filthy appearance, surveillance method
1 概况
神华国华太仓发电有限公司装有2×630 MW 超临界机组,其主参数如下:过热蒸汽流量1913 t/h,过热蒸汽出口温度571℃,压力25.40MPa;再热蒸汽流量1586t/h,再热蒸汽出口温度569℃,压力4.16MPa。两台机组分别于2005 年11 月8 日和2006 年1 月20 日投入商业运行。
公司化学补给水处理系统采用了反渗透预除盐+二级除盐设备,凝结水采用100%处理的前置过滤器+高速混床系统。给水加药系统设计了AVT(R)处理方式和OT 处理方式。两台机组商业运行半年内的检修中,发现省煤器垢量都非常高,达280g/m2 以上,但由于工期紧张,无法当期处理,只好推迟到下次检修中进行。首次A 级检修机组完成化学清洗后,尝试使用
锅炉压差变化情况来推断受热面结垢情况,并相应地准备治理方案。这种方式时间充裕,研讨评估深入,准备充分,为下一步有效治理打下了良好的基础。在检修割管后分析表明,压差变化判断是可靠的,治理方案便得以顺利实施,取得了预期的效果。
本文
锅炉压差用机组满负荷时的省煤器进口至启动分离器出口的压力差值表示。锅炉设计定型后在一定负荷运行时的基础压差基本已确定。直流锅炉运行时,压差上升速度就只与锅炉炉管内部所结垢的成分、表面形态、结垢速率等因素有关。其中化学水工况决定垢的表面形态,进而决定压差上升趋势,是压差上升的主要影响因素。
下面通过宏观分析和微观分析,揭示给水化学工况与
锅炉压差的关系和影响机理。