贵宾会员zhuh提供---热电厂水汽系统
氢电导率超标原因分析
李建华,郑敏聪,潘娟琴
(安徽省电力科学研究院,安徽合肥,230022)
[摘 要
] 本文对某热电厂水汽系统
氢电导率超标原因进行了分析。在对该机组水汽系统
阴离子含量、
总有机碳含量、可溶性气体进行分析的基础上,得出机组补水量偏大是导致该机组水汽系统
氢电导率超标的主要原因,同时
氢电导率测量用离子交换柱内树脂乱层现象也对
氢电导率有影响。
Cause Analysis on Water and Steam Cation Conductivity Over-Standard in
Cogeneration Power Plant
Li Jianhua,Zheng mincong
(Anhui Electric Power Research Institute,Hefei,230022)
ABSTRACT: The cause of water and steam cation conductivity over-standard in cogeneration power plant was analyzed in the paper. After measured and studied the quality of water and steam, such as the content of anion, total organic carbon(TOC) and soluble gas, etc, the causes of failure had been found out. The predominant cause was the higher of the makeup water quantity for condenser. In addition, the turbostratic state of the cation exchange resin in the column also influenced the cation conductivity.
KEY WORDS: Cation Conductivity, Anion, Total Organic Carbon, Makeup Water Quantity for Condenser
1 前言
某热电厂#12 机组锅炉为东方锅炉厂生产的DGJ480/13.7-Ⅱ1 型超高压中间再热自然循环汽包炉,汽轮机为北重汽轮电机有限责任公司生产的NC135-13.24/1.27/535/535 型超高压中间再热双缸双排汽抽凝式汽轮机,发电机为北重汽轮电机有限责任公司生产的Qfa-135-2 空冷发电机。该机组于2007 年4 月投产后,夏天的供汽量在50t/h 左右,冬天的供汽量在100t/h 左右。
该机组锅炉补给水为100%除盐水,补给水水源为长江水,经混凝澄清预处理,采用一级除盐+混床处理。锅炉给水采用加氨和联氨的AVT(R)处理,炉水采用磷酸盐处理。
表1 表示的是该热电厂#12 机组2009 年1~7 月份水汽系统凝结水和给水
氢电导率范围及其合格率统计。
从表中可以看出,其凝结水
氢电导率在0.17~2.32μS/cm 之间,平均合格率仅为32.89%,给水
氢电导率在0.10~2.46μS/cm 之间,平均合格率仅为51.10%。同时,在该机组水汽系统
氢电导率超标期间,凝结水硬度为零、钠含量也在合格范围,表明凝汽器不锈钢管没有泄漏,引起水汽系统
氢电导率超标的原因并不是凝汽器泄漏。
氢电导率是综合反映热力系统水汽品质的重要指标,
氢电导率越大,表明水汽对热力设备的腐蚀和危害程度也越大[1]。因此,有必要尽快对该机组水汽系统
氢电导率超标的原因进行分析。