贵宾会员zhuh提供----200MW供热机组基加泄漏对水汽品质的影响
张文梅 任渊峰 刘志勇
(太原第二热电厂 山西 太原 030041)
[摘 要] 在供热期间基本加热器泄漏,疏水回收后对整个系统的水汽品质产生较大的影响,引起给水电导率、钠含量超标,炉水pH 值超标,蒸汽电导率超标,对其原因进行了分析,并提出增加疏水钠含量的测定。
Influence of water and steam quality by primary calorifier leakage of 200MW heat-supply unit
Zhang wenmei Ren yuanfeng Liu zhiyong
(Taiyuan Second Thermal Power Plant Shanxi Taiyuan 030041)
ABSTRACT: Primary calorifier leakage in the period of heat-supply, it is a great influence to the whole system of water
and steam quality ,after recover the condensate, which caused conductivity and sodium of feed water, pH of boiler water,
conductivity of steam over standard, then analyze the reasons and suggest to add the determination of condensate sodium ion.
KEY WORDS: primary calorifier leakage ; condensate; water and steam quality.
1 设备简介
太原第二热电厂200MW 7 号、8 号、9 号供热机组相继于1992 年、1993 年、2003 年投产,锅炉为超高压中间再热自然循环煤粉炉,汽轮机为超高压中间再热三缸二排汽供热抽汽凝汽式汽轮机。由锅炉来的主蒸汽通过高压缸,进入中间再热器后,进入中压缸,再进入低压缸,排汽在表面式凝汽器中与空冷塔来的冷却水进行热交换而凝结成水,凝结水(无凝结水精处理设备)经四台低压加热器,一台除氧器和三台高压加热器预热除氧后,返回锅炉。
热网系统内基本加热器,型号JR-2650 中州汽轮机厂生产,换热面积2650m2,水侧压力2.7MPa, 加热汽源取至汽机六段抽汽,基加疏水至4 号低加入口门疏水处进入。
200MW 机组热网补给水处理由机械过滤器和一级钠离子软化器组成,最大出力100t/h,软化水硬度≤200μmol/L。
2 问题的提出
2.1 根据有关工程热网系统的运行经验,由于热网补充水的氯离子和硫酸根含量高,而这些阴离子对不锈钢的腐蚀性较强,系统运行几年后,加热站的不锈钢加热器及热膨胀节相继出现腐蚀泄漏现象。
2.2 通过对我厂供热期间基加泄漏,疏水回收后的试验数据进行监督分析,发现基加泄漏,回收后的基加疏水对整个系统的水汽品质产生较大的影响,直接影响机组的安全经济运行。在我厂的现场运行控制中,对疏水只监控硬度,只要硬度合格,就可以回收。但是由于热网补给水为软化水,疏水硬度会很快合格。基加泄漏,首先引起基加疏水Na+超标,回收后的基加疏水使给水、蒸汽的氢电导率超标,为保证水汽品质合格,只能开大连排,增加定排。
3 分析与讨论
3.1 我们将2008 年1 月21 日9#机组基加泄漏期间和8 号机组基加正常运行水汽指标进行对比。
3.2 我们对软化水进行了水质测定(表1)